  • table 3-9. boiler exhaust gas volumetric flow rate

    Table 3-9. Boiler Exhaust Gas Volumetric Flow Rate

    Avg. Fuel Heat Run GCV Flow Consumption Fd O2 Flow No. (Btu/ft3) (mmft3/day) (mmBtu/hr) (dscf/mmBtu) (%d) (dscfm) --- ----- ----- ----- ----- ---- ----- 1 1034 93.8

    View More
  • johnston boiler company boiler glossary

    Johnston Boiler Company Boiler Glossary

    What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP = (LB/HR*fe)/34.5 BHP = 21500 * 1.08 / 34.5 BHP = 673 Where, BHP boiler horsepower Lb/Hr pounds per …

    View More
  • residential gas archives | velocity boiler works

    Residential Gas Archives | Velocity Boiler Works

    Aruba 5 (AWR) The Aruba 5 Series (AWR) residential, cast iron, hot water boiler is a fully-packaged, installer-ready product. The rear draft diverter provides a low profile design that allows for closet applications on smaller sizes. This atmospheric, gas-fired boiler is for use with a conventional chimney.

    View More
  • boiler feedwater | instrumart

    Boiler Feedwater | Instrumart

    Flow meters are useful for measuring the flow rates of both steam and feedwater. As water flows throughout the boiler its chemical properties can damage the system so feedwater is often treated to control alkalinity, prevent scaling, correct pH, and to control conductivity.

    View More
  • boiler flow rates explained - local boiler quotes

    Boiler Flow Rates Explained - Local Boiler Quotes

    Nov 05, 2015 · Flow Rates & Boiler Power Requirements. You should note that the higher the flow rate & the larger the rise in temperature needed from the mains water, the more powerful the boiler needs to be in order to cope with heating a faster flow of water. If you want hot water at 9 litres per minute, what amount of heating power do you need from your

    View More
  • boiler horsepower - engineering toolbox

    Boiler Horsepower - Engineering ToolBox

    Boiler horsepower - a power unit from the 19 th-20 th centuries - was used to rate the capacity of a boiler to deliver steam to steam engines.. A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) - with feed water at pressure 0 psig and temperature 212 o F.

    View More
  • boiler selection considerations - cleaver-brooks

    BOILER SELECTION CONSIDERATIONS - Cleaver-Brooks

    Boiler horsepower (BHP) is a measure of boiler energy output. One boiler horsepower (from and at 212 °F): † BHP = 34.5 lbs/hr † BHP = 33,472 Btu/hr † BHP = 9.8 kW † BHP should not be confused with other horsepower measurements. Boiler Trim: Accessories added to the boiler, such as auxiliary low water cutoff, special tappings, special gas

    View More
  • general engineering data - complete boiler room solutions

    General Engineering Data - Complete Boiler Room Solutions

    Table 1 shows capacity of a natural gas line for a given initial pressure with a 5% pressure drop. For example, consider a 500 hp boiler, which requires 20,925 cu.-ft. / hr. A 5 psi initial pressure is available for 100 ft. of pipe. To find the correct pipe size, go to the line for initial gas pressure reading 5 pounds. Now move to the

    View More
  • calculators and tools | velocity boiler works

    Calculators and Tools | Velocity Boiler Works

    Velocity Boiler Works 3633 I Street, Philadelphia, PA 19134 Phone (215) 535-8900. Velocity Boiler Works is the sole marketer of Crown Boiler cast iron boiler products.

    View More
  • boiler controls &boiler controls & instrumentation

    BOILER CONTROLS &BOILER CONTROLS & INSTRUMENTATION

    5. Boiler will trip if Deaerator low low level switch isBoiler will trip if Deaerator low low level switch is activatedactivated 6.6. Boiler will trip is ID fan trips Boiler will trip is ID fan trips 7 Boiler will trip if instrument air pressure fails 24/06/201024/06/2010 THERMODYNE TECHNOLOGIES PRIVATE LIMITEDLIMITED 23

    View More
  • commonly used hvac formulae and conversions

    Commonly Used HVAC Formulae and Conversions

    1 lb/h = 4.5 Q 1 ton = Q∆h/2670 cfm x static pressure (in. w.g.) Density of air 6356 x Efficiency Density of standard air Small fans 0.40 – 0.50 efficiency Large fan 0.55 – 0.60 efficiency For Water: 1 lb/h = 500 gpm 1 ton = (gpm) ∆t/24 gpm x ft head 3960 x

    View More
  • boiler formulas - johnston boiler

    Boiler Formulas - Johnston Boiler

    Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / 34.5 …

    View More
  • blowdown in boiler | boiler blowdown calculation formula

    Blowdown in Boiler | Boiler Blowdown Calculation Formula

    Blowdown in Boiler Definition. Blowdown in Boiler, Usually, water which is fed to the boiler contains high Total Dissolved Solids (TDS) content as well as other dissolved and undissolved solids in it. On heating water or converting water to steam, these dissolved solids do not evaporate and gets separated from water or steam and settled at the bottom of the shell.

    View More
  • boiler – fundamentals and best practices

    Boiler – Fundamentals and Best Practices

    Steam Production When heat is added to water, its temperature rises at a rate of 0.56°C (1°F) for each heat input of 2.095 kJ/kg (1 Btu/lb) If we take water at 0°C (32°F) and we

    View More
  • boilers | energy-models

    BOILERS | Energy-Models

    Figure 2.3 Water Tube Boiler: Water tube or "water in tube" boilers in which the conditions are reversed with the water passing through the tubes and the hot gasses passing outside the tubes (see figure 2.3). These boilers can be of single- or multiple-drum type. These boilers can be built to any steam capacities and pressures, and have higher efficiencies than fire tube boilers.

    View More
  • water handbook - boiler blowdown control | suez

    Water Handbook - Boiler Blowdown Control | SUEZ

    The line must also be located so that boiler feedwater or chemical feed solution does not flow directly into it. The size of the lines and control valves depends on the quantity of blowdown required. Figure 13-4 illustrates a typical location in a steam drum for a continuous blowdown connection .

    View More
  • flow rate from boiler to storage | hearth forums home

    Flow Rate From Boiler to Storage | Hearth Forums Home

    Feb 19, 2013 · Based on the specs of the loading unit maximum flow may be less than boiler output, even at relatively "high" delta-T. Assume output of 160,000 btu, assume maximum loading unit flow rate of 12 gpm (actual spec on one loading unit is a little less than 12 gpm), assume pump head will allow full 12 gpm with the loading unit: If delta-T=30, this

    View More
  • gas flow conversions (mass, standard, actual) calculator

    Gas Flow Conversions (mass, standard, actual) Calculator

    In the gas flow discipline, flowrates are often expressed as "flow at standard conditions". Standard conditions are synonymous with the term "base conditions" or "normal conditions". The calculation on this page converts between mass flow (W), flow at standard conditions (Q s), and flow at actual (flowing) conditions (Q a). The equations use SI